Choosing LAN Cabling Options

Several types of cables and connectors can be used in LANs, depending on the require-ments for the network and the type of Ethernet to be implemented. These connectors also vary depending on the type of media that you have installed.

Learning about the different types of cables and connectors in an Ethernet LAN and their various functions can help you understand more about how a LAN works.

LAN Physical Layer

Ethernet is the most widely used LAN technology. Since its initial implementation, Ethernet has been extended to four new types:

  • 802.3u (Fast Ethernet)

  • 802.3z (Gigabit Ethernet over Fiber)

  • 802.3ab (Gigabit Ethernet over UTP)

  • 802.3ae (10 Gigabit Ethernet)

The cabling aspects of the LAN exist at Layer 1 of the Open System Interconnection (OSI) reference model. Figure 4-7 shows a subset of physical layer implementations that can be deployed to support Ethernet.

Figure 7Figure 4-7 Ethernet at the Physical Layer

Ethernet in the Campus

Before implementing a network, you need to determine the requirements for the network. You can remember a few common recommendations on how various Ethernet technologies can be used in a campus network environment.

In many modern installations, infrastructure costs for cabling and adapters can be high. Using the appropriate Ethernet connectivity provides the necessary speed for the parts of the network that require it while controlling costs.

In general, you can use Ethernet technologies in a campus network in several different ways:

  • An Ethernet speed of 10 Mbps can be used at the access layer to provide adequate performance for most users. In addition, 100-Mbps Fast Ethernet can be used for high-bandwidth-consuming clients or servers.

  • Gigabit Ethernet is typically used as the link between the access layer and network devices, supporting the aggregate traffic from each Ethernet segment on the access link.

  • To enhance client-server performance across the campus network and avoid bottlenecks at the server, Fast Ethernet or Gigabit Ethernet links can be used to connect enterprise servers. Gigabit Ethernet, in combination with switched Fast Ethernet, creates an effective solution for avoiding slow networks.

  • Gigabit Ethernet links can provide the connection between the distribution layer and the core. Because the campus network model supports dual links between each distribution layer router and core switch, you can load balance the aggregate traffic from multiple-access switches across the links.

  • Gigabit Ethernet (or 10 Gigabit Ethernet) should be used between switches and the backbone. The fastest affordable media should be implemented between backbone switches.

Table 4-2 outlines the recommendations for Ethernet deployment.

Table 4-2 Ethernet Connectivity Recommendations

Network Hierarchy Layer

Ethernet 10 Mbps

Fast Ethernet 100 Mbps

Gigabit Ethernet 1000 Mbps

10 Gigabit Ethernet 10000 Mbps

Access layer

Connects users with low to moderate bandwidth requirements

Connects users with high-speed requirements or servers with low to moderate usage

Connects servers with high usage

Not currently recommended at this layer

Distribution layer

Not recommended at this layer

Connects routers and switches with moderate usage

Interconnects access switches with Fast Ethernet users and used to connect distribution switches to core layer

Not currently recommended at this layer

Core layer

Not recommended at this layer

Not recommended at this layer

Interconnects core switches in networks with moderate use

Interconnects core switches with high usage


NOTE

Currently, some organizations are considering providing Gigabit Ethernet to the end user; however, not many applications can take full advantage of this infrastructure, and providing Gigabit Ethernet to the end user can potentially create a bottleneck between network devices. You should consider this carefully before installing gigabit technology to the end users.

Ethernet Media and Connector Requirements

In addition to considering the requirements for the Ethernet LAN, the media and connector requirements for each implementation must be considered. This topic outlines the cable and connector specifications used to support Ethernet implementations.

The cable and connector specifications used to support Ethernet implementations are derived from the Electronic Industries Alliance and (newer) Telecommunications Industry Alliance (EIA/TIA) standards body. The categories of cabling defined for Ethernet are derived from the EIA/TIA-568 (SP-2840) Commercial Building Telecommunications Wiring Standards. EIA/TIA specifies an RJ-45 connector for UTP cable. The letters RJ stand for registered jack, and the number 45 refers to a specific physical connector that has eight conductors.

Table 4-3 compares the cable and connector specifications for the most popular Ethernet implementations.

The important difference to note is the media used for 10-Mbps Ethernet versus 100-Mbps Ethernet. In today's networks, in which you see a mix of 10- and 100-Mbps requirements, you must be aware of the need to change over to UTP Category 5 to support Fast Ethernet.

Connection Media

Several connection media can be used in an Ethernet LAN implementation. Figure 4-8 illustrates different connection types—attachment unit interface (AUI), RJ-45, and gigabit—used by each physical layer implementation. The RJ-45 connector and jack are the most prevalent. RJ-45 connectors are discussed in more detail later in this chapter.

In some cases, the type of connector on a NIC does not match the type of media that it needs to connect to. As shown in Figure 4-8, an interface exists for the AUI connector on many Cisco devices. The AUI is the 15-pin physical connector interface between a computer's NIC and coaxial Ethernet cable.

Table 4-3 TCable and Connector Specifications

 

10BASE-2

10BASE-5

10BASE-T

100BASE-TX

100BASE- FX

1000 BASE-CX

1000 BASE-T

1000 BASE-SX

1000 BASE-LX

Media

50-ohm coaxial (Thinnet) RG-58 coaxial cable

50-ohm coaxial (Thicknet)

RG-50 coaxial cable

EIA/TIA Category 3, 4, 5 UTP 2 pair

EIA/TIA Category 5 UTP 2 pair

62.5/125 micro multimode fiber

STP

EIA/TIA Category 5 UTP 4 pair

62.5/50 micro multimode fiber

9 micro single-mode fiber

Maximum Segment Length

185 m (606.94 ft)

500 m (1640.4 ft)

100 m (328 ft)

100 m (328 ft)

400 m (1312.3 ft)

25 m (82 ft)

100 m (328 ft)

260 m (853 ft)

3-10 km (1.86–6.2 miles)

Topology

Bus

Bus

Star

Star

Point-to-point

Star or point-to-point

Star or point-to-point

Point-to-point

Point-to-point

Connector

AUI or BNC connector

AUI

ISO 8877 (RJ-45)

ISO 8877 (RJ-45)

MT-RJ or SC connector

ISO 8877 (RJ-45)

ISO 8877 (RJ-45)

SC

SC


A Gigabit Interface Converter (GBIC), like the one shown in Figure 4-9, is a hot-swappable input/output device that plugs into a Gigabit Ethernet port. A key benefit of using a GBIC is that GBICs are interchangeable. This allows users the flexibility to deploy other 1000BASE-X technology without needing to change the physical interface/model on the router or switch. GBICs support UTP (copper) and fiber-optic media for Gigabit Ethernet transmission.

Figure 9Figure 4-9 GBIC

<Anchor0>

Typically, GBICs are used in the LAN for aggregation and in the backbone. You also see GBICs in SANs and MANs.

The fiber-optic GBIC is a transceiver that converts serial electric currents to optical signals and optical signals to digital electric currents. Some of the optical GBICs include the following:

  • Short wavelength (1000BASE-SX)

  • Long wavelength/long haul (1000BASE-LX/LH)

  • Extended distance (1000BASE-ZX)

UTP Implementation

In a UTP implementation, you must determine the EIA/TIA type of cable and whether to use a straight-through or crossover cable. This section describes the types of connectors used in a UTP implementation and the characteristics and uses of straight-through and crossover cables.

If you look at an RJ-45 transparent end connector, like the one in Figure 4-10, you can see eight colored wires, twisted into four pairs. Four of the wires (two pairs) carry the positive or true voltage and are considered tip (T1 through T4); the other four wires carry the inverse of false voltage grounded and are called ring (R1 through R4). Tip and ring are terms that originated in the early days of the telephone. Today, these terms refer to the positive and the negative wires in a pair. The wires in the first pair in a cable or a connector are designated as T1 and R1, the second pair is T2 and R2, and so on.

Figure 10Figure 4-10 RJ-45 Connector

The RJ-45 plug is the male component, crimped at the end of the cable. As you look at the male connector from the front (the side with the metal pins exposed), the pin locations are numbered from 8 on the left to 1 on the right.

The RJ-45 jack, shown in Figure 4-11, is the female component in a network device, wall, cubicle partition outlet, or patch panel.

Figure 11Figure 4-11 RJ-45 Jack

In addition to identifying the correct EIA/TIA category of cable to use for a connecting device (depending on what standard is being used by the jack on the network device), you need to determine which of the following to use:

  • A straight-through cable

  • A crossover cable

The RJ-45 connectors on both ends show all the wires in the same order. If the two RJ-45 ends of a cable are held side by side in the same orientation, the colored wires (or strips or pins) are seen at each connector end. If the order of the colored wires is the same at each end, the cable is straight-through. Figure 4-12 shows the wiring for a straight-through cable.

Figure 12Figure 4-12 Straight-Through Cable Wiring

With crossover, the RJ-45 connectors on both ends show that some of the wires on one side of the cable are crossed to a different pin on the other side of the cable. Specifically, for Ethernet, pin 1 at one RJ-45 end should be connected to pin 3 at the other end. Pin 2 at one end should be connected to pin 6 at the other end, as shown in Figure 4-13.

Figure 13Figure 4-13 Crossover Cable Wiring

Each device using RJ-45 connectors transmits or receives on particular pins depending on the device type. A PC or router typically transmits on pins 1 and 2 while a switch or hub receives on pins 1 and 2. You must follow certain guidelines when connecting these devices.

Use straight-through cables for the following cabling:

  • Switch to router

  • Switch to PC or server

  • Hub to PC or server

Use crossover cables for the following cabling:

  • Switch to switch

  • Switch to hub

  • Hub to hub

  • Router to router

  • PC to PC

  • Router to PC

Occasionally, ports on network devices are marked with an X, like those in Figure 4-14. This marking means that these devices receive on pins 1 and 2, or that they are crossed. When connecting devices in a network, you might be required to use a variety of cable types.

NOTE

Most hubs and some switches have a port that can be changed from X to not-X by moving a switch or pressing a button. This feature enables you to use straight-through cables where crossovers would ordinarily be required.

Figure 14Figure 4-14 RJ-45 Port Designations

Being aware of the different cabling media types, specifications, and connectors is an important step to interconnecting network devices.

InformIT Promotional Mailings & Special Offers

I would like to receive exclusive offers and hear about products from InformIT and its family of brands. I can unsubscribe at any time.

Overview


Pearson Education, Inc., 221 River Street, Hoboken, New Jersey 07030, (Pearson) presents this site to provide information about products and services that can be purchased through this site.

This privacy notice provides an overview of our commitment to privacy and describes how we collect, protect, use and share personal information collected through this site. Please note that other Pearson websites and online products and services have their own separate privacy policies.

Collection and Use of Information


To conduct business and deliver products and services, Pearson collects and uses personal information in several ways in connection with this site, including:

Questions and Inquiries

For inquiries and questions, we collect the inquiry or question, together with name, contact details (email address, phone number and mailing address) and any other additional information voluntarily submitted to us through a Contact Us form or an email. We use this information to address the inquiry and respond to the question.

Online Store

For orders and purchases placed through our online store on this site, we collect order details, name, institution name and address (if applicable), email address, phone number, shipping and billing addresses, credit/debit card information, shipping options and any instructions. We use this information to complete transactions, fulfill orders, communicate with individuals placing orders or visiting the online store, and for related purposes.

Surveys

Pearson may offer opportunities to provide feedback or participate in surveys, including surveys evaluating Pearson products, services or sites. Participation is voluntary. Pearson collects information requested in the survey questions and uses the information to evaluate, support, maintain and improve products, services or sites, develop new products and services, conduct educational research and for other purposes specified in the survey.

Contests and Drawings

Occasionally, we may sponsor a contest or drawing. Participation is optional. Pearson collects name, contact information and other information specified on the entry form for the contest or drawing to conduct the contest or drawing. Pearson may collect additional personal information from the winners of a contest or drawing in order to award the prize and for tax reporting purposes, as required by law.

Newsletters

If you have elected to receive email newsletters or promotional mailings and special offers but want to unsubscribe, simply email information@informit.com.

Service Announcements

On rare occasions it is necessary to send out a strictly service related announcement. For instance, if our service is temporarily suspended for maintenance we might send users an email. Generally, users may not opt-out of these communications, though they can deactivate their account information. However, these communications are not promotional in nature.

Customer Service

We communicate with users on a regular basis to provide requested services and in regard to issues relating to their account we reply via email or phone in accordance with the users' wishes when a user submits their information through our Contact Us form.

Other Collection and Use of Information


Application and System Logs

Pearson automatically collects log data to help ensure the delivery, availability and security of this site. Log data may include technical information about how a user or visitor connected to this site, such as browser type, type of computer/device, operating system, internet service provider and IP address. We use this information for support purposes and to monitor the health of the site, identify problems, improve service, detect unauthorized access and fraudulent activity, prevent and respond to security incidents and appropriately scale computing resources.

Web Analytics

Pearson may use third party web trend analytical services, including Google Analytics, to collect visitor information, such as IP addresses, browser types, referring pages, pages visited and time spent on a particular site. While these analytical services collect and report information on an anonymous basis, they may use cookies to gather web trend information. The information gathered may enable Pearson (but not the third party web trend services) to link information with application and system log data. Pearson uses this information for system administration and to identify problems, improve service, detect unauthorized access and fraudulent activity, prevent and respond to security incidents, appropriately scale computing resources and otherwise support and deliver this site and its services.

Cookies and Related Technologies

This site uses cookies and similar technologies to personalize content, measure traffic patterns, control security, track use and access of information on this site, and provide interest-based messages and advertising. Users can manage and block the use of cookies through their browser. Disabling or blocking certain cookies may limit the functionality of this site.

Do Not Track

This site currently does not respond to Do Not Track signals.

Security


Pearson uses appropriate physical, administrative and technical security measures to protect personal information from unauthorized access, use and disclosure.

Children


This site is not directed to children under the age of 13.

Marketing


Pearson may send or direct marketing communications to users, provided that

  • Pearson will not use personal information collected or processed as a K-12 school service provider for the purpose of directed or targeted advertising.
  • Such marketing is consistent with applicable law and Pearson's legal obligations.
  • Pearson will not knowingly direct or send marketing communications to an individual who has expressed a preference not to receive marketing.
  • Where required by applicable law, express or implied consent to marketing exists and has not been withdrawn.

Pearson may provide personal information to a third party service provider on a restricted basis to provide marketing solely on behalf of Pearson or an affiliate or customer for whom Pearson is a service provider. Marketing preferences may be changed at any time.

Correcting/Updating Personal Information


If a user's personally identifiable information changes (such as your postal address or email address), we provide a way to correct or update that user's personal data provided to us. This can be done on the Account page. If a user no longer desires our service and desires to delete his or her account, please contact us at customer-service@informit.com and we will process the deletion of a user's account.

Choice/Opt-out


Users can always make an informed choice as to whether they should proceed with certain services offered by InformIT. If you choose to remove yourself from our mailing list(s) simply visit the following page and uncheck any communication you no longer want to receive: www.informit.com/u.aspx.

Sale of Personal Information


Pearson does not rent or sell personal information in exchange for any payment of money.

While Pearson does not sell personal information, as defined in Nevada law, Nevada residents may email a request for no sale of their personal information to NevadaDesignatedRequest@pearson.com.

Supplemental Privacy Statement for California Residents


California residents should read our Supplemental privacy statement for California residents in conjunction with this Privacy Notice. The Supplemental privacy statement for California residents explains Pearson's commitment to comply with California law and applies to personal information of California residents collected in connection with this site and the Services.

Sharing and Disclosure


Pearson may disclose personal information, as follows:

  • As required by law.
  • With the consent of the individual (or their parent, if the individual is a minor)
  • In response to a subpoena, court order or legal process, to the extent permitted or required by law
  • To protect the security and safety of individuals, data, assets and systems, consistent with applicable law
  • In connection the sale, joint venture or other transfer of some or all of its company or assets, subject to the provisions of this Privacy Notice
  • To investigate or address actual or suspected fraud or other illegal activities
  • To exercise its legal rights, including enforcement of the Terms of Use for this site or another contract
  • To affiliated Pearson companies and other companies and organizations who perform work for Pearson and are obligated to protect the privacy of personal information consistent with this Privacy Notice
  • To a school, organization, company or government agency, where Pearson collects or processes the personal information in a school setting or on behalf of such organization, company or government agency.

Links


This web site contains links to other sites. Please be aware that we are not responsible for the privacy practices of such other sites. We encourage our users to be aware when they leave our site and to read the privacy statements of each and every web site that collects Personal Information. This privacy statement applies solely to information collected by this web site.

Requests and Contact


Please contact us about this Privacy Notice or if you have any requests or questions relating to the privacy of your personal information.

Changes to this Privacy Notice


We may revise this Privacy Notice through an updated posting. We will identify the effective date of the revision in the posting. Often, updates are made to provide greater clarity or to comply with changes in regulatory requirements. If the updates involve material changes to the collection, protection, use or disclosure of Personal Information, Pearson will provide notice of the change through a conspicuous notice on this site or other appropriate way. Continued use of the site after the effective date of a posted revision evidences acceptance. Please contact us if you have questions or concerns about the Privacy Notice or any objection to any revisions.

Last Update: November 17, 2020